Chapter 9  Operation and Maintenance
■ Server Management Tools Error Messages
The following error messages may appear while executing Server Management Tools. Perform the 
corresponding resolution listed in the table. If messages other than the following are displayed, contact 
an office listed in the "Contact Information" of the "Start Guide".
Power supply fan status is warning PSU fan rotation error. Replace the PSU fan. If the message still 
appears, the baseboard must be replaced. Contact an office listed 
in the "Contact Information" of "Start Guide".
Power supply fan status is critical
System fan status is warning System fan rotation error. Replace the system fan. If the 
message still appears, the baseboard must be replaced. Contact 
an office listed in the "Contact Information" of "Start Guide".
System fan status is critical
System board voltage status is warning Baseboard voltage error. The baseboard must be replaced. 
Contact an office listed in the "Contact Information" of "Start 
Guide".
System board voltage status is critical
Ambient temperature status is warning Ambient temperature error. Check the environment where the 
server is used. If the message still appears, the ambient 
temperature sensor or the baseboard must be replaced. Contact 
an office listed in the "Contact Information" of "Start Guide".
Ambient temperature status is critical
Memory module error Memory module error. Check the installed memory and replace 
it if necessary. If the message still appears, the baseboard must 
be replaced. Contact an office listed in the "Contact 
Information" of "Start Guide".
System temperature status is warning Baseboard temperature error. Check the environment where the 
server is used. If the message still appears, the baseboard must 
be replaced. Contact an office listed in the "Contact 
Information" of "Start Guide".
System temperature status is critical
No Usable CPU Installed CPU error. Replace the CPU. If the message still 
appears, the baseboard must be replaced. Contact an office listed 
in the "Contact Information" of "Start Guide". After the 
replacement, enable the CPU in the BIOS Setup Utility.
No Usable Memory Memory error. Check the error log and replace the memory 
module. If the message still appears, the baseboard must be 
replaced. Contact an office listed in the "Contact Information" 
of "Start Guide". After the replacement, enable the use of the 
memory in the BIOS Setup Utility.
RAID configuration Error Onboard RAID error. Replace the cache memory for onboard 
RAID. If the message still appears, the baseboard must be 
replaced. Contact an office listed in the "Contact Information" 
of "Start Guide".
table: List of Server Management Tools Error Messages
Message Description
Write protect error writing drive A.
Abort, Retry, Fail?
The inserted floppy disk is write-protected. Disable the 
write-protect, and then press the [R] key.
Not ready writing drive A.
Abort, Retry, Fail?
The floppy disk is not inserted into the floppy disk 
drive. Insert the proper floppy disk ("Server 
Management Tools" floppy disk), and then press the 
[R] key.
table: List of POST error messages
Message Description