EasyManua.ls Logo

Furuno NAVNET TZ2 TZTL12F - Fuse Replacement; Life of Parts

Furuno NAVNET TZ2 TZTL12F
420 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
16. MAINTENANCE, TROUBLESHOOTING
16-2
16.2 Fuse Replacement
The fuse in the fuse holder in the power cable protects the equipment from high elec-
tric current and equipment fault. If you cannot turn on the power, check the fuse to see
if it has blown. Find the reason for the blown fuse before you replace the fuse. If the
fuse blows again after the replacement, contact your dealer for advice.
16.3 Life of Parts
Magnetron
When a magnetron reaches the end of its life, targets do not appear on the radar dis-
play. If long-range performance appears to have declined, contact your dealer about
replacement of the magnetron.
The total time of power-on ("ON TIME") and transmission ("TX TIME") are displayed
on the radar screen during the stand-by mode.
LCD (TZTL12F/TZTL15F only)
The life of the LCD for the TZTL15F is approximately 18,000 hours; for the TZTL12F
it is approximately 25,000 hours. The actual life of the LCD is affected by the operating
environment (temperature, humidity, etc.). When nearing the end of its life-span, the
LCD brilliance does not adjust correctly. When this occurs, contact your local dealer
for advice.
Name Type Code No. Remarks
Fuse FGBO-A 125V 5A PBF 000-155-853-10 12 VDC, 24 VDC
Radar Sensor Magnetron Code No. Approx. Life
DRS4DL 80-0691 001-266-460 5,000 hours
DRS4DL+ 80-0691 001-266-460 5,000 hours
DRS6A X-Class MAF1422B 000-158-788-12 5,000 hours
DRS12A X-Class FNE1201 001-245-890 5.000 hours
DRS25A X-Class MG5436 001-205-570 5,000 hours
WARNIN
WARNING
Use the proper fuse.
Use of the wrong fuse can cause fire or
electrical shock.

Table of Contents

Related product manuals