System wiring notes
Table 33 explains the various component functionality as shown in Figure 29 on page 165 and Figure 30 on
page 166.
Table 26. System wiring notes
1
Class 2 power transformer must be plugged into an
unswitched AC power receptacle. Do not short the
transformer terminals together. The transformer contains
an internal fuse that permanently disables the output if
the terminals are shorted.
2
Speaker terminals 7 and 8 activate for Partition 1 alarms
only. Use speakers with 8 ohm or higher impedance. Use
18 ga. stranded wire. When connecting two or more
8 ohm speakers, wire them in series as shown. Wiring
speakers in parallel can permanently damage the panel.
3
Output 1 is +12 V switched, rated for 1 A maximum.
Default configuration number 01614 activates output 30
seconds after a fire or intrusion alarm occurs. Output 2 is
open-collector type rated for 300 mA maximum. Default
configuration number 01710 activates output for status
and alarm sounds. Refer to panel installation instructions
for all possible settings. The total current sourced from
terminals 4, 7, 8, 9, 11, 24, and all snapcard terminals (if
used) is limited to 1.0 A maximum.
4
Connect multiple piezo sirens in parallel.
5
Zone (loop) wiring shown is an example that applies to all
zones (except when zone 8 is configured for 2-wire smoke
detectors). Install EOL resistors across all unused zone
(loop) inputs.
6
For UL listed installations, wire multiple supervised 2-wire
hardwired smoke detectors (20 maximum) only as shown.
Maximum 120 µA current draw per detector. Maximum
90 mA current draw in alarm.
7
Some telephones are polarity-sensitive. Green and red
wires may need to be reversed.
8
SuperBus 2000 alphanumeric touchpads required for
onsite programming (models 60-746-01, 60-803, 60-804,
60-983, 60-984, or 60-985). For normal operation and
programming, a SuperBus 2000 fixed display touchpad
(60-820) or SuperBus 2000 FTP 1000 touchpad may be
used. Maximum 16 bus devices per panel (all partitions).
9
A maximum of two audio verification modules (60-677)
are allowed (Partition 1 only). Wire multiple speakers in
series; power and microphone wires in parallel. Use
shielded cable to prevent crosstalk between the speaker
and microphone. Audio verification modules shall not be
used in UL listed installations.
bk
Use 60-681 (12 VDC, 4.5 or 5 Ah) or 60-680 (12 VDC, 7 Ah)
backup battery. Battery is automatically tested every 24
hours (every 4 hours with UL 98 options set on). Replace
only with exact replacement. Without AC power, panel
will shut down if battery voltage falls below 10.2 VDC.
bl
Refer to the SuperBus 2000 4-Relay Output Module
Installation Instructions for device connections to module
outputs.
bm
Refer to the SuperBus 2000 Energy Saver Module
Installation Instructions for thermostat wiring details.
bn
Connect hardwired zones to module inputs the same as
those shown for the panel. Install EOL resistors across all
unused zone inputs. Refer to the SuperBus 2000 8Z
Module Installation Instructions for complete details.

Table of Contents

Other manuals for GE Security Concord 4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE Security Concord 4 and is the answer not in the manual?

GE Security Concord 4 Specifications

General IconGeneral
BrandGE Security
ModelConcord 4
CategorySecurity System
LanguageEnglish

Related product manuals