Chapter 3
Programming
67
Activity timeout (0306)
Default setting is 24 hours.
This setting determines when the system sends a no activity report. The panel can be set to wait from 1 to 42
hours. If no user interaction or device activation occurs in that time, the panel sends a report to the central
station. To set the Activity timeout, do the following:
1. With the display showing ACTIVITY TIMEOUT nn HOURS (current setting), enter the number of
hours (1 to 42).
2. The display flashes the entered setting. Press # and the display shows the new setting.
Daylight saving (0307)
Default setting is On.
When this setting is on, the panel clock automatically adjusts for daylight saving time changes. To turn
daylight saving off or on, do the following:
1. With the display showing DAYLIGHT SAVING OFF/ON (current setting), press 1 (off) or 2 (on).
2. The display flashes the entered setting. Press # and the display shows the new setting.
Timers - partition 1 to 6 settings
The following sections describe the Timers menu settings that appear under Partition 1 to 6.
Entry delay (0310 to 0360)
Default setting is 30 seconds.
This setting determines how much time you have to disarm the system (after entering the armed premises
through a designated delay door) without causing an alarm.
Note: For UL 1023 listed installations, the Entry delay must be set to 45 seconds or less. The combined time for the Entry delay
and Dialer abort delay (02006) must not exceed 60 seconds.
To set the Entry delay, do the following:
1. With the display showing ENTRY DELAY nnn SECS (current setting), enter the time value (30 to
240 seconds).
2. The display flashes the entered setting. Press # and the display shows the new setting.
Exit delay (0311 to 0361)
Default setting is 60 seconds.
This setting determines how much time you have (after arming the system) to leave the premises through a
designated delay door without causing an alarm.
Note: For UL 1023 listed installations, this feature must be set to 60 seconds or less. For UL 1610 listed installations, this
feature must be set to 120 seconds or less.

Table of Contents

Other manuals for GE Security Concord 4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE Security Concord 4 and is the answer not in the manual?

GE Security Concord 4 Specifications

General IconGeneral
BrandGE Security
ModelConcord 4
CategorySecurity System
LanguageEnglish

Related product manuals