Concord 4
Installation Manual
94
4. Remove AC and battery power from the panel.
5. Replace the defective bus device with a new one.
6. Apply AC and battery power to the panel.
Partition assign
This menu lets you assign bus devices to work in the desired partition.
Note: SuperBus 2000 8Z input modules, SuperBus 2000 4-relay output modules, and SuperBus 2000 RF receivers are not
assigned to partitions.
To assign bus devices to partitions, do the following:
1. With the display showing the desired bus device, press #.
2. Press A or B until the display shows DEVICE PTN and then press #. The display shows PARTITION
ASSIGN n.
3. Press 1 to 6 to select the desired partition. The display flashes the entered selection. Press # and the
display shows the new setting.
Output programming
Use these settings to program the output points of any installed SuperBus 2000 hardwire output module. The
installer programs a HOM output point into the Concord security panel by entering three kinds of information.
Partition. The system partition (1 to 6).
Trigger. The event that activates the output point. Trigger events can be partition alarms, trouble
conditions, open sensors, etc. (see Appendix C, Reference tables).
Response. How the output responds to a trigger event.
Only the onboard and SnapCard outputs can be configured for user control.
To program each of the HOM output point configurations into the security panel, do the following:
1. With the display showing the desired bus device, press #.
2. Press A or B until the display shows OUTPUTS.
3. Press #. The display shows OUTPUT 1.
4. Press A or B to select an output, then press #. The display shows PARTITION ASSIGN 1.
5. Press 1 to 6 to select the desired partition assignment for this relay. The display flashes the entered
setting. Press # and the display shows the new setting.
6. Press A or B. The display shows CONFIGURATION tttrr (current setting). The point
configuration number is tttrr, where ttt is the trigger number and rr is the response number.
7. Enter the desired five-digit configuration number for this relay. The display flashes the entered setting.
Press # and the display shows the new setting.
8. Press # and repeat the process until all outputs are programmed.