Chapter 3
Programming
73
Reporting menu
The Reporting menu lets you set up which system events are reported to the central monitoring station that
affect the whole system (see Reporting - global settings) or a specific partition (Reporting - partition 1 to 6
settings on page 78).
Reporting - global settings
The following describes how to program the Reporting menu settings that appear under Global.
24-hour tamper (06000)
Default setting is Off.
When this setting is turned on, the panel sounds sirens and reports a tamper alarm (even when the system is
disarmed), when nonfire wireless sensor tamper switches are activated.
When this setting is turned off, the panel sounds sirens and reports a tamper alarm only when nonfire wireless
sensor tamper switches are activated and those sensors are active for the current arming level. For nonfire
sensors not active in the current arming level that have their tamper switch activated, trouble beeps sound and
the panel sends a sensor tamper report to the central station if the System tamper feature is on for that partition.
Note: Tamper conditions for fire sensors (group 26) always cause trouble beeps to sound and report the tamper condition to
the central station, regardless of this feature setting. For commercial UL listed installations (UL 1610) the 24-hour tamper
must be set to on.
To turn the setting off or on, do the following:
1. With the display showing 24 HOUR TAMPER OFF/ON (current setting), press 1 (off) or 2 (on).
2. The display flashes the entered setting. Press # and the display shows the new setting
.
Antenna tamper (06001)
Default setting is Off.
This setting determines whether the panel monitors for antenna tamper of onboard and all connected bus
transceivers and receivers. When turned on, the panel sounds trouble beeps in all partitions and reports an
antenna tamper condition. Touchpads in all partitions show a receiver tamper trouble condition. When turned
off, the panel ignores antenna tampers.
Note: If the system includes SuperBus 2000 RF receivers, this setting must be off.
To turn the setting off or on, do the following:
1. With the display showing ANTENNA TAMPER OFF/ON (current setting), press 1 (off) or 2 (on).
2. The display flashes the entered setting. Press # and the display shows the new setting.

Table of Contents

Other manuals for GE Security Concord 4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE Security Concord 4 and is the answer not in the manual?

GE Security Concord 4 Specifications

General IconGeneral
BrandGE Security
ModelConcord 4
CategorySecurity System
LanguageEnglish

Related product manuals