Buffer control (06002)
Default setting is Off.
When this setting is on, only arming level changes and time changes (system time and daylight saving time)
are logged in the buffer (memory) of the panel. When this setting is off, all system events are logged in the
buffer.
To turn the setting off or on, do the following:
1. With the display showing BUFFER CONTROL OFF/ON (current setting), press 1 (off) or 2 (on).
2. The display flashes the entered setting. Press # and the display shows the new setting.
Back in service (06003)
Default setting is On.
When this setting is on, the panel reports to the central station when AC and backup battery power are restored
(after an extended power outage).
To turn the setting off or on, do the following:
1. With the display showing BACK IN SERVICE OFF/ON (current setting), press 1 (off) or 2 (on).
2. The display flashes the entered setting. Press # and the display shows the new setting.
Bypass reports (06004)
Default setting is Off.
When this setting is on, the panel reports to the central station whenever sensors or zones are bypassed.
To turn the setting off or on, do the following:
1. With the display showing BYPASS REPORTS OFF/ON (current setting), press 1 (off) or 2 (on).
2. The display flashes the entered setting. Press # and the display shows the new setting.
Low CPU battery (06005)
Default setting is On.
When this setting is on, the panel reports a low panel battery to the central station when the system battery test
fails. If this setting and the Aux power fail feature are both on, the panel also monitors for and reports a low
battery for the SuperBus 2000 2-amp power supply.
Note: For UL 1635 listed installations, the Low CPU battery feature must be set to on.
To turn the setting off or on, do the following:
1. With the display showing LOW CPU BATTERY OFF/ON (current setting), press 1 (off) or 2 (on).
2. The display flashes the entered setting. Press # and the display shows the new setting.