This table shows what the sensors on your Concord 4 system do. Every sensor is assigned to a group, and this
table specifies those groups and functions. Every device must be assigned to one of these groups.
Table 25. Sensor group characteristics
No. Name Application Alarm Delay Restoral
Supervi
sory
CS
Report
Chime
(Level)
Active
levels
00 Fixed panic 24-hour audible fixed
emergency buttons.
Police Instant 1,2,3
01 Portable
panic
24-hour audible portable
emergency buttons.
Police Instant 1,2,3
02 Fixed panic 24-hour silent fixed
emergency buttons.
Silent Instant 1,2,3
03 Portable
panic
24-hour silent portable
emergency buttons.
Silent Instant 1,2,3
04 Fixed
auxiliary
24-hour auxiliary sensor,
such as Pendant Panic or
holdup button.
Auxiliary Instant 1,2,3
05 Fixed
auxiliary
24-hour auxiliary
emergency button. Siren
shutoff confirms CS
report.
Auxiliary Instant 1,2,3
06 Portable
auxiliary
24-hour portable auxiliary
alert button.
Auxiliary Instant 1,2,3
07 Portable
auxiliary
24-hour portable auxiliary
button. Siren shutoff
confirms CS report.
Auxiliary Instant 1,2,3
08 Special
intrusion
Special belongings, such
as gun cabinets and wall
safes.
Police Instant 1,2,3
09 Special
intrusion
Special belongings (i.e.
gun cabinets and wall
safes.)
Police Standard 1,2,3
10 Entry/exit
delay
Entry and exit doors that
require a standard delay
time.
Police Standard 2,3
11 Entry/exit
delay
Garage doors and
entrances that require an
extended delay time. *
Police Extended 2,3
12 Entry/exit
delay
Driveway gates and
entrances that require a
twice extended delay
time. *
Police Twice
extended
2,3