161
14 Instant
interior
Interior doors (Hardwired) Police Follower 2,3
15 Instant
interior
Interior PIR motion
sensors. * (RF wireless)
Police Follower 2,3
16 Instant
interior
Interior doors. (Hardwired) Police Follower 3
17 Instant
interior
PIR motion sensors *(RF
wireless.)
Police Follower 3
18 Instant
interior
Instant interior cross-
zone# PIR motion sensors.
* †
Police Follower 3
19 Delayed
interior
Interior doors that initiate
a delay before going into
alarm. *
Police Interior 3
20 Delayed
interior
PIR motion sensors that
initiate a delay before
going into alarm. *
Police Standard 3
21 Local
instant
interior
24-hour local alarm zone
protecting anything
thatopens and closes.
Police Instant 1,2,3
22 Local
delayed
interior
Same as group 21, plus
activation initiates a delay
before going into alarm.
Police Standard 1,2,3
23 Local
instant
auxiliary
24-hour local alarm zone
protecting anything that
opens and closes. ‡
Auxiliary Instant 1,2,3
24 Local
instant
auxiliary
24-hour local alarm zone
protecting anything that
opens and closes. Sirens
shut off at restoral. *
Auxiliary Instant 1,2,3
25 Local
special
chime
Notify the user when a
door is opened. Sounds
emit from a local
annunciator. *
Special
chime
Instant 1,2,3
26 Fire 24-hour fire, rate-of-rise
heat, and smoke sensors.
Fire Instant 1,2,3
27 Output
module
Hardwire Output Module
(HOM) lamp control or
other customer feature. ‡
Silent Instant 1,2,3
28 Output
module
HOM, PIR motion sensor,
sound sensor or pressure
mat. ‡
Silent Instant 1,2,3
Table 25. Sensor group characteristics (continued)
No. Name Application Alarm Delay Restoral
Supervi
sory
CS
Report
Chime
(Level)
Active
levels