Concord 4
Installation Manual
70
Light control menu
The Light control menu lets you set up light activation for a specific partition.
Note: For light control to work, you must power the panel with a power line carrier transformer and X10 powerhouse lamp
modules must be installed at desired lamps.
Light control - partition 1 to 6 settings
The following describes how to program the Light control menu settings that appear under Partition 1 to 6.
Entry lights (0400 to 0450)
Default setting is None.
This setting determines which X10 controlled lights turn on during entry and exit delays.
Note: X10 lamp modules set to 1 always turn on during the entry and exit delays. X10 lamp modules set to 2 always flash the
arming level when arming the system. For example, lights flash two times when arming to STAY (level 2), and three times
when arming to AWAY (level 3).
To set the entry lights, do the following:
1. With the desired partition selected, press #. The display shows ENTRY LIGHTS nnnnnnn (current
setting).
2. Enter all the desired light numbers (3 to 9) based on the unit dial setting on each X10 lamp module.
3. The display flashes the entered settings. Press # and the display shows the new settings.
To delete entry lights, enter any light number that appears on the display, then press #. The number disappears
from the display.
House code (0401 to 0451)
Default setting is 01 B for partition 1, 02 C for partition 2, 03 D for partition 3, 04 E for partition 4, 05 F for
partition 5, and 06 G for partition 6.
This setting enables X10 controlled lights to work in a selected partition without interfering with the X10
controlled lights of the other partitions. After setting the panel house code for each partition, you must set the
X10 controlled lights for that partition to the same house code. The letter that appears automatically after the
house code number indicates the necessary house dial setting for X10 modules in that partition.
To set the House code, do the following:
1. After you select your partition, press A or B until the display shows HOUSE CODE nn-x (current
setting). Enter the number (1 to 255).
2. The display flashes the entered number. Press # and the display shows the new house code.

Table of Contents

Other manuals for GE Security Concord 4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE Security Concord 4 and is the answer not in the manual?

GE Security Concord 4 Specifications

General IconGeneral
BrandGE Security
ModelConcord 4
CategorySecurity System
LanguageEnglish

Related product manuals