Global fire (0703)
Default setting is Off.
This setting determines whether or not sirens in all partitions sound (on) if any partition activates a fire alarm.
To turn the setting off or on, do the following:
1. With the display showing GLOBAL FIRE OFF/ON (current setting), press 1 (off) or 2 (on).
2. The display flashes the entered setting. Press # and the display shows the new setting.
Silent panic (0704)
Default setting is Off.
This setting determines whether touchpad police panic alarms are audible (off) or silent (on).
To turn the setting off or on, do the following:
1. With the display showing GLOBAL SILENT PANIC OFF/ON (current setting), press 1 (off) or 2
(on).
2. The display flashes the entered setting. Press # and the display shows the new setting.
Siren options - Partition 1 setting
The following describes the Siren option menu setting that appears under Partition 1.
Silent verify (0710)
Default setting is Off.
This setting determines whether the panel supervises the panel speaker terminals (7 and 8). When this feature is
on, the panel indicates a trouble condition if no speaker is connected to panel speaker terminals.
Note: For UL listed installations, this setting must be on.
To turn the setting off or on, do the following:
1. With the display showing SIREN VERIFY OFF/ON (current setting), press 1 (off) or 2 (on).
2. The display flashes the entered setting. Press # and the display shows the new setting.