Onboard options - output programming settings
The following section describe the Onboard options menu settings that appear under Output programming.
Output 1, 2
Shortcuts are: Output 1 partition assignment (11100), configuration (11101); Output 2 partition assignment
(11110), configuration (11111).
Default setting is Ptn 1, 01614 for Output 1 and Ptn 1, 01710 for Output 2.
This setting assigns the partition and the five-digit configuration number for the two onboard outputs. The
configuration number determines
• Which system event activates the selected output.
• The duration or time the output is activated.
The first three digits represent the trigger number of an event (such as triggering an alarm, opening a sensor, or
arming the system). The last two digits represent how the output responds, For example, momentary switching,
maintained (or latched) switching, or switching for a preset time.
Note: If you want to configure an output for user Output control you must use the Output text feature to name the output. If
no output text is programmed, user Output control will not function for that output.
Use the system event trigger and response numbers listed in. See Appendix C, Reference tables.
To set up onboard Output 1 and 2 partition and configuration assignments, do the following:
1. With the display showing ONBOARD OPTIONS, press # + B. The display shows OUTPUT
PROGRAMMING.
2. Press # and the display shows OUTPUT 1. Press B to select OUTPUT 2.
3. Press # and the display shows PARTITION ASSIGN n (current setting).
4. Press 1 to 6 to assign the output to the desired partition, then press #. The display shows PARTITION
ASSIGN (new setting).
5. Press B and the display shows CONFIGURATION tttrr (current setting).
6. Enter the configuration number. The display flashes the entered number. Press # and the display shows
the new setting.
7. Press # and repeat the process until all outputs are programmed.