SuperBus 2000 bus devices
You may use the following components with the Concord 4 panel.
You may use the following touchpads for installer/user programming and system operation.
• SuperBus 2000 2x16 LCD touchpad
• SuperBus 2000 2x20 LCD touchpad
• SuperBus 2000 2x20 VFD touchpad
• SuperBus 2000 ATP 1000 touchpad
• SuperBus 2000 ATP 2100 touchpad
• SuperBus 2000 ATP 2600 touchpad
• SuperBus 2000 GTS 50 touchpad
You may use the following touchpads for installer quick programming, system operation and user
programming:
• SuperBus 2000 fixed display touchpad
• SuperBus 2000 FTP 1000 touchpad
SuperBus 2000 RF transceiver. You may use the transceiver to receive signals from sensors and
touchpad that may be on the fringe of panel reception. The transceiver is compatible with all 319.5 MHz
crystal and SAW learn mode wireless sensors and touchpads.
SuperBus 2000 RF receiver. You may use the receiver to receive signals from sensors and touchpad that
may be on the fringe of panel reception. The receiver is compatible with all 319.5 MHz. crystal and SAW
learn mode wireless sensors and touchpads.
Note: If installing this module, you must turn off the antenna tamper feature.
Power line carrier transformer. Using this transformer allows the use of X10 powerhouse lamp modules
for light control and light activation during alarms.
SuperBus 2000 voice only module. This module provides an output for a speaker that sounds system
status and alarm voice messages.
SuperBus 2000 phone interface/voice module. This module allows system access and control using
touchtone telephones, onsite or offsite. The module includes an output for a speaker that sounds system
status and alarm voice messages.
SnapCards. The following SnapCards expand the system as described:
• 8Z input SnapCard: Provides eight additional hardwired zone inputs, of which two are dedicated for
using two-wire smoke detectors.
• 4 output SnapCard: Provides four form C relay outputs that can be set up to activate other signaling
devices, based on system events, schedules, or direct control.
• 4Z input/2 output combo SnapCard: Provides three hardwired zone inputs, one two-wire smoke
detector loop, and two outputs that can be set up to activate other signaling devices, based on system
events, schedules, or direct control.
SuperBus 2000 8Z input module (HIM). Provides eight additional hardwire zone inputs.
SuperBus 2000 4-relay output module (HOM). Provides four form C relay outputs that can be set up to
activate other signaling devices, based on system events.