Aux power fail (06016)
Default setting is On.
When this setting is on, the panel sends a report to the central monitoring station if the 12 VDC power outputs
on the panel and/or SuperBus 2000 2-amp power supply fail.
Note: If this feature is on and the AC failure and Low CPU battery features are both on, the panel sends AC failure and low
backup battery reports for the SuperBus 2000 2-amp power supply.
To turn the setting off or on, do the following:
1. With the display showing AUX POWER FAIL ON/OFF (current setting), press 1 (off) or 2 (on).
2. The display flashes the entered setting. Press # and the display shows the new setting.
Ground fault (06017)
Default setting is On.
When this setting is on, the panel will annunciate and send a report to the central monitoring station if it detects
current flow between the panel’s circuitry and the chassis. This indicates that a short to earth ground exists
somewhere in the system.
Note: This feature must be on if hardwired smoke sensors are used in this system.
To turn the setting off or on, do the following:
1. With the display showing GROUND FAULT OFF/ON (current setting), press 1 (off) or 2 (on).
2. The display flashes the entered setting. Press # and the display shows the new setting.
Reporting - partition 1 to 6 settings
The following describes the Reporting menu settings that appear under Partition 1 to 6.
Opening reports (06100 to 06600)
Default setting is Off.
When this setting is on, the panel sends an opening report to the central station after disarming the system.
Note: To use this feature, the Open/close reports settings under the Phones menu on page 53 must be turned on for the
specific CS phone or pager number.
To turn the setting off or on, do the following:
1. With the display showing OPENING REPORTS OFF/ON (current setting), press 1 (off) or 2 (on).
2. The display flashes the entered setting. Press # and the display shows the new setting.
Closing reports (06101 to 06601)
Default setting is Off.
When this setting is on, the panel sends a closing report to the central station after arming the system.