Chapter 3
Programming
77
RF low battery report (06013)
Default setting is Weekly.
This setting determines whether the panel sends daily or weekly low battery reports to the central monitoring
station when a wireless device is reporting a low battery condition to the panel.
To set RF low battery report to daily or weekly, do the following:
1. With the display showing RF LOW BAT RPT DAILY/WEEKLY (current setting), press 1 (daily) or
2 (weekly).
2. The display flashes the entered setting. Press # and the display shows the new setting.
RF supv report (06014)
Default setting is Weekly.
This setting determines whether the panel sends daily or weekly reports to the central monitoring station when
the panel detects a supervisory condition in a wireless device.
To set RF Supv Report to daily or weekly, do the following:
1. With the display showing RF SUPV REPORT DAILY/WEEKLY (current setting), press 1 (daily) or
2 (weekly).
2. The display flashes the entered setting. Press # and the display shows the new setting.
Swinger limit (06015)
Default setting is 1.
This setting determines the maximum number of times (1 or 2) a sensor or zone can go into alarm (during a
single arming period) before the panel automatically bypasses that sensor or zone. This feature only applies to
sensors or zones in groups 00–20, 29, 34, 35, or 38.
When set to 1, the panel automatically bypasses a sensor or zone after it causes an alarm. When set to 2, the
panel waits until a sensor or zone has caused a second alarm (during the same arming period) before bypassing
it. At any setting, the automatic bypass is logged into the event buffer.
A bypassed sensor or zone will be cleared (automatically unbypassed) if the system receives no further
activations from that sensor or zone over the next 48 to 50 hours.
Changing the arming level also clears all automatically bypassed sensors and zones and resets the Swinger
limit count on all sensors and zones.
To set the Swinger limit, do the following:
1. With the display showing SWINGER LIMIT n (current setting), press the desired number (1 or 2).
2. The display flashes the entered setting. Press # and the display shows the new setting.

Table of Contents

Other manuals for GE Security Concord 4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE Security Concord 4 and is the answer not in the manual?

GE Security Concord 4 Specifications

General IconGeneral
BrandGE Security
ModelConcord 4
CategorySecurity System
LanguageEnglish

Related product manuals