TP panic TRPT FMT (06010)
Default setting is Off.
This setting determines how the panel formats touchpad panic alarm reports to the central station. When this
feature is turned on, touchpad panic alarms report using the following 3-digit codes:
Auxiliary—597
Police—598
•Fire599
When turned off, touchpad panic alarms report using a 3-digit code from 500 to 515, with the last 2 digits
identifying the touchpad device number.
To turn the setting off or on, do the following:
1. With the display showing TP PANIC RPT FMT OFF/ON (current setting), press 1 (off) or 2 (on).
2. The display flashes the entered setting. Press # and the display shows the new setting.
AC failure (06011)
Default setting is Off.
When this setting is on, the panel reports to the central station at a random time between 15 and 45 minutes
after AC power to the panel is lost. Making the report random helps prevent systems in an area affected by a
power outage from trying to report at the same time.
Note: If this feature and the Aux power fail feature are both on, the panel also monitors for and reports an AC failure for the
SuperBus 2000 2-amp power supply. For UL listed installations, AC failure must be set to on.
To turn the setting off or on, do the following:
1. With the display showing AC FAILURE OFF/ON (current setting), press 1 (off) or 2 (on).
2. The display flashes the entered setting. Press # and the display shows the new setting.
Receiver failure (06012)
Default setting is Off.
When this setting is on, the panel reports a receiver failure under the following conditions:
No wireless sensor signals have been received for two hours.
The receiver is being jammed with a constant signal.
Note: For UL listed installations using wireless devices, Receiver failure must be set to on.
To turn the setting off or on, do the following:
1. With the display showing RECEIVER FAILURE OFF/ON (current setting), press 1 (off) or 2 (on).
2. The display flashes the entered setting. Press # and the display shows the new setting.

Table of Contents

Other manuals for GE Security Concord 4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE Security Concord 4 and is the answer not in the manual?

GE Security Concord 4 Specifications

General IconGeneral
BrandGE Security
ModelConcord 4
CategorySecurity System
LanguageEnglish

Related product manuals