Chapter 3
Programming
75
Battery restoral (06006)
Default setting is Off.
If this setting is on, the panel reports to the central monitoring station when a wireless sensor or touchpad
reports a battery replacement to the panel.
To turn the setting off or on, do the following:
1. With the display showing BATTERY RESTORAL OFF/ON (current setting), press 1 (off) or 2 (on).
2. The display flashes the entered setting. Press # and the display shows the new setting.
Buffer full report (06007)
Default setting is Off.
When this setting is on, the panel sends an event buffer full report to the central monitoring station when the
event buffer is nearing full. When turned off, no report is sent.
To turn the setting off or on, do the following:
1. With the display showing BUFFER FULL RPT OFF/ON (current setting), press 1 (off) or 2 (on).
2. The display flashes the entered setting. Press # and the display shows the new setting.
Zone restorals (06008)
Default setting is Off.
When this setting is on, the panel reports a restoral to the central monitoring station for wireless or hardwire
zones in alarm before the alarm is canceled.
Note: As with all GE Security panels, hardwired smoke detectors connected to panel or SnapCard hardwired zones do not
send restorals.
To turn the setting off or on, do the following:
1. With the display showing ZONE RESTORALS OFF/ON (current setting), press 1 (off) or 2 (on).
2. The display flashes the entered setting. Press # and the display shows the new setting.
Two-trip (06009)
Default setting is Off.
This setting works with the Alarm verify setting (see Alarm verify (06108 to 06608) on page 81 and
Appendix C, Reference tables). If Alarm verify is on, the panel waits for a second sensor trip before sending an
alarm.
Note: For UL listed installations, the Two trip error feature must be off.
If Two-trip is on and a second sensor trip does not occur within a four-minute time period, the panel sends an
error report to the central monitoring station. To turn the setting off or on, do the following:
1. With the display showing TWO-TRIP ERROR OFF/ON (current setting), press 1 (off) or 2 (on).
2. The display flashes the entered setting. Press # and the display shows the new setting.

Table of Contents

Other manuals for GE Security Concord 4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE Security Concord 4 and is the answer not in the manual?

GE Security Concord 4 Specifications

General IconGeneral
BrandGE Security
ModelConcord 4
CategorySecurity System
LanguageEnglish

Related product manuals