Chapter 3
Programming
113
Note: The low setpoint cannot be set equal to or higher than the high setpoint.
To set the low setpoint, do the following:
1. With the display showing Energy Saver, press #, then A or B until the display shows LOW
SETPOINT NN DEGREES (current setting).
2. Enter the desired temperature (45 to 89°F). The display flashes the entered setting. Press # and the
display shows the new setting.
High setpoint (071)
Default setting is 90°F.
This setting determines the temperature at which the energy saver module relay closes to activate the air-
conditioner.
Note: The high setpoint cannot be set equal to or lower than the low setpoint.
To set the high setpoint, do the following:
1. With the display showing ENERGY SAVER, press #, then A or B until the display shows HIGH
SETPOINT nn DEGREES (current setting).
2. Enter the desired temperature (46 to 90°F). The display flashes the entered setting. Press # and the
display shows the new setting.
Attach lights to sensors menu
The Attach lights to sensors menu lets you assign a light number to a sensor. Each time the sensor is activated,
the attached light will turn on for 5 minutes. When the 5-minute timer expires the light will turn off. If the same
light is scheduled, it will only turn on during the schedule time.
Light X to Sensor Y (08n where n is light number minus 1)
Default setting is 0.
This menu attaches light x to sensor y. Each time a selected sensor is tripped, the selected light will turn on and
a 5-minute timer will start. The sensor must be learned into the current partition before it can be attached
To attach a light to a sensor, do the following:
1. With the display showing LIGHT 1 TO SENSOR y (current setting), press A or B to select the light
number.
2. Enter the sensor number (01 to 96). The display flashes the entered setting. Press # and the display
shows the new setting.
3. Repeat the process until all desired lights are attached to sensors.
To detach a light from a sensor, do the following:
1. With the display showing LIGHT 1 TO SENSOR y (current setting), press A or B to select the light
number.
2. Enter 0 as the sensor number and press #.

Table of Contents

Other manuals for GE Security Concord 4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE Security Concord 4 and is the answer not in the manual?

GE Security Concord 4 Specifications

General IconGeneral
BrandGE Security
ModelConcord 4
CategorySecurity System
LanguageEnglish

Related product manuals