Term Definition
Keyfob User ID A menu option that makes the keyfob report as the zone that it is learned into.
When this option is disabled, all keyfobs report their open/closing reports as
user 99.
Learn RF Keypad A menu command that triggers the learn-in mode for the RF keypad.
Learn RF Sir/IO A menu command that triggers the learn-in mode for the siren or IO module.
Learn RF Zone A menu command that triggers the learn-in mode for the RF zone (sensor).
Learn-RF Device A menu option that enables the mode in which a new wireless device is
enrolled on the system.
Log Event A menu option that specifies whether the output switching on and off is
logged.
Model A menu option that displays the model of the selected receiver.
Normal Window A menu option that specifies the normal supervision window for RF devices. RF
devices on 868 MHz typically report every 15 minutes. Depending on the
country regulations, this timer must be set to specific values.
Option 1 A menu option used for configuring a sensor. For actual setting description, see
the particular sensor manual. For example, in case of a keyfob it enables the
keyfob function 1 (see below).
Option 2 A menu option used for configuring a sensor. For actual setting description, see
the particular sensor manual. For example, in case of a keyfob it enables the
keyfob function 2 (see below).
Option 3 A menu option used for configuring a sensor. For actual setting description, see
the particular sensor manual.
Output Latched A menu option that specifies the way the output is timed. If set to Yes, the
output will latch until a code is entered. When set to No, the output is timed
according to Time setting.
Note: Do not set up this option for system status events (such as "Ready to
Arm", "Not Ready to Arm", "Armed", "Disarmed") because once the output is
triggered it will not reset to reflect current status unless the user code is
entered.
Outputs A menu entry that groups programmable options for IO modules.
Partitions A menu entry that lists the partitions assigned to the selected keyfob. The
selected keyfob can trigger an event on these partitions.
A zone may reside in any combination of partitions. A zone that resides in more
than one partition becomes a common zone and is reported to its lowest
partition number. A common zone is armed only when all the partitions that it
belongs to are armed. It is disarmed the moment one of the partitions it
belongs to is disarmed.
Partitions Selects the partition(s) that will trigger the output when the event occurs in
these partition(s).