NetworX Version 3 Installation Manual
221
Term Definition
Partition Account
Codes
A Reporting menu entry that lists the account codes for each partition. The account code is sent
when the relevant partition is reported. There are two sets of account codes. The first set assigns an
account code to each report destination. The second set assigns an account code to each partition. If
you attempt to use both sets, the partition account code takes precedence.
See also Account Code
Password
An Options setting that configures the password for a PAP login. Contact the network provider to
confirm if a PAP login is required and to obtain the user ID and password.
Password Always
Required
An Options menu setting that requires a password to be included when a HomeText message is sent
to the system. Passwords must be between 6 and 16 characters and contain at least one number
between
0-9. They should only have alphanumeric characters and no spaces.
Phone Number A Reporting setting that sets the phone number to which SMS reports are sent.
An Up/download setting that sets the phone number of the PC running the upload/download
software.
Polling Time A Reporting setting that configures the length of theTCP/IP polling time.
This value must match the TCP/IP polling time set on a TCP/IP receiver. The value chosen is
determined by the level of security required and the cost of data transmission. This can be from 1 to
255 minutes on the NX-7002 and 1 to 255 seconds on the NX-590. If set to 0, the option is disabled.
Polling Units A Reporting setting that sets polling time in either hours or minutes.
Port Numbers An Options menu entry that groups TCP/IP port options.
Power A Options menu entry that groups power related status messages.
Power
A Reporting menu entry that groups the power events that are reported to the selected report
control.
Power Trouble and
Restores
A Reporting setting that reports mains failure, mains restore, low battery and low battery restore
events to the selected report control.
Primary reporting The main means of reporting selected events.
See also Secondary reporting
Program/Download
A Reporting setting that reports programming and up/download events to the selected report
control.
Protocol
A Reporting setting that configures the communicator format used to report to the selected SMS
receiver. Consult the instructions for your central station receiver to determine which format is
compatible.
PUK code
Personal Unblocking Key. The code to use to unblock the SIM card. The SIM card can block when an
incorrect SIM PIN is entered repeatedly.
R
Receiver Number
A Reporting setting that configures the phone line receiver number associated with the receiver
account.
Receiver Polling A Reporting setting that configures the NX-7002 to send polling messages to the report receivers.
Receivers A Reporting menu entry that groups TCP/IP receiver options.
Registered Phone
Access
A Reporting menu entry that lists all the users with rights to send HomeText commands from the
phone registered in the system.
Note: Only users listed here are granted rights to send HomeText commands to the system.
Removing a user from this list suspends all user's rights to send HomeText commands, including Any
Phone Access privileges.
Relay Unrecognised
SMS to Admin
An Options menu option, that if enabled, sends any unrecognised text messages to the administrator.

Table of Contents