NetworX Version 3 Installation Manual
83
Location Term Definition
2.4.4.2.1.4 RF Sensor Lost A menu option that sends a report to the central station,
when an RF sensor is missing.
RF sensors send out supervision signals every 15 or 64
minutes, depending on the frequency. An RF receiver must
receive these signals within a specified time window. This
window is set by the Supervision timer. If the RF receiver
does not receive these signals during the time window, the
RF sensor is considered missing.
2.4.4.2.1.5 RF Low Battery A menu option that sends a report to the central station
when a low battery condition occurs in an RF sensor.
2.4.4.2.1.6 CleanMe A menu option that sends a report to the central station
when a smoke detector is dirty.
2.4.4.2.2 Power A menu entry that groups the power events that are
reported to the central station.
2.4.4.2.2.1 Mains Failure A menu option that sends a report to the central station
when the mains power supply fails. A delay time can be set
for this report.
2.4.4.2.2.2 Low Battery A menu option that enables low battery reporting on the
control panel.
2.4.4.2.2.3 Aux Overcurrent A menu option that enables overcurrent reporting. A report
is sent to the selected central station when too much
current is drawn from a device powered by the system.
2.4.4.2.3 Communications A menu entry that groups together the communication
events that are reported to the central station.
2.4.4.2.3.1 Phone Line Cut A menu option that sends a report is sent to the central
station the moment the phone line cut is restored.
2.4.4.2.3.2 Fail to Communicate A menu option that sends a report to the central station
when the system has failed to communicate with the
central station after the number of attempts set in Dial
Attempts. The report is sent when communication with the
central station has been restored.
2.4.4.2.3.3 Autotest A menu option that enables reporting of autotest events to
the central station at a specified interval.
2.4.4.2.3.4 Autotest only when Armed A menu option that allows test calls to be made only when
the system is armed.
2.4.4.2.4.1 Log Full A menu option that sends a report to the central station
when the event log is full.
2.4.4.2.4.2 Start/End Programming A menu option that causes reports to be sent to a specified
phone number. A report is sent when local programming
begins and ends.
2.4.4.2.4.3 End Download A menu option that sends a report to the central station
when downloading from the up/download software to the
control panel is complete.
2.4.4.2.5 Bypass on Force Arm A menu option that enables bypass reporting when a zone
is force armed.