NetworX Version 3 Installation Manual
90
Location Term Definition
2.5.1.2.4.2 Tamper if Zone Lost A menu option that sends a report to the central station
when a wireless zone sensor is lost and activates a tamper
alarm. Different reports are sent depending on the system
status. When armed the tamper and the lost report are
sent. When disarmed only the lost report is sent.
2.6 System Settings A menu entry that groups programmable system features
and reporting options.
2.6.1 Timers A menu entry that groups timer options.
2.6.1.1 Zones A menu entry that groups time settings relating to zones.
2.6.1.1.1 Fire Verification Time A menu option that sets the amount of time within which a
second trip must occur on a smoke detector in order to
generate an alarm.
2.6.1.1.2 Zone Inact. Unit A menu option that allows the zone inactivity option to be
configured in hours or days.
2.6.1.1.3 Zone Activity Monitor A menu option that sets the zone inactivity time. It is
possible to specify this time in minutes or hours.
2.6.1.1.4 Cross Zone Timer A menu option that sets the cross zone time in minutes.
This can be from 0 to 255 minutes, where 0 = no cross
zoning.
2.6.1.2 Power A menu entry that groups the timer options relating to
power events.
2.6.1.2.1 Batt Dynamic Test Duration A menu option that sets the length of time that the control
panel performs the Dynamic Battery test. This can be
between 0 to 30 minutes where 0 is no test.
2.6.1.2.2 Mains Report Delay A menu option that sets the length of time between
detecting a mains failure on the control panel and sending
a report to the central station. The restore event is sent
four minutes after the mains is restored.
2.6.1.2.3 Power Up Delay A menu option that sets the time between mains restore
after a power failure and the system powering up again.
This can be set from 0-60 seconds. 0 means no power up
delay.
2.6.1.3 Sounders A menu entry that groups timers for the internal siren,
external siren and chime duration on the keypad.
2.6.1.3.1 Internal Siren Timeout A menu option that sets the length of time the internal
siren rings before automatically cutting out. This time can
be between 0 and 255 minutes. When set to 0, the siren is
active until a valid code is entered on the keypad.
2.6.1.3.2 Chime Time A menu option that sets the length of time that the chime
operates. This time can be set in 50 ms (1/20th second)
increments from 0-12 seconds. 0 = follows zone.
2.6.1.4 Communications A menu option that groups timers for communication
events.