NetworX Version 3 Installation Manual
91
Location Term Definition
2.6.1.4.1 Dialer Abort Delay A menu option that creates a delay, programmed in
seconds, in reporting an alarm to the central station.
2.6.1.4.2 Listen-in Time A menu option that sets the length of time the central
station can listen for sounds of intrusion by means of
microphones at the alarm site.
2.6.1.4.3 Phone Line Cut Delay A menu option that sets the length of time before a phone
line cut is signalled after a phone line cut is detected.
A phone line fault is displayed in Service Check>Reset when
Phone Line Cut Delay = 0.
2.6.1.5.1 Programming Mode Timeout A menu option that sets the length of time the control
panel can be in programming mode. This time can be
between 1 and 255 minutes. When set to 0, the
programming mode times out after 15 minutes.
2.6.1.5.2 Auto Arm Warning Time A menu option that sets the length of the warning signal
emited during auto arming. This time can be between 1
and 255 minutes, with 1 minute being a default value.
2.6.1.5.3 Auto Arm Retry Timer A menu option that sets the auto arm cycle timer. This time
can be between 1 and 255 minutes, with 45 minutes as a
default value.
2.6.2 Feature Select A menu entry that groups all optional features relating to
control panel system settings.
2.6.2.1 Inputs A menu entry that groups options that enable features
relating to inputs.
2.6.2.1.1 On-board zones A menu option that disables the wired zones on the control
panel. This provides a completely wireless alarm system.
2.6.2.1.2 Box Tamper A menu option that enables the box tamper switch on the
control panel. The NetworX V3 has an input for a normally
closed tamper switch. When opened, a box tamper is
reported as an event.
2.6.2.1.3 ExitError limited to EE1 A menu option that limits the Exit Error to
Entry/Exit Delay 1.
2.6.2.1.4 Double Pulse A menu option that will allow two trips on the same cross-
zone to activate an alarm.
2.6.2.1.5 Force Default Zone Types A menu option that uses the default zone types in the
country defaults for the selected country rather than
configured zone types.
2.6.2.1.6 A+B/Cross Zone When this feature is enabled, a first trigger from a zone will
send a BG report (unverified alarm or B-alarm) for that
zone. The B-alarm message will be written in the log. In
addition, a fix 30 minute timer will start. If a zone is
triggered for a 2nd time within the 30 minutes time frame,
this zone will send a BA report (burglary alarm or verified
alarm) to the monitoring station. If there is no 2nd zone
that was triggered within 30 minutes, the timer will be
cleared. A+B alarm reporting only works with intrusion
zone types using the SIA formats. When this feature is
enabled, the standard cross-zoning feature will be inactive.