Inside a 1 to 12 Loop Self-Contained Panel Box
Inside a 1 to 3 Loop Panel Box
LOOP 1
OUT
LOOP 2
OUT
LOOP 3
OUT
LOOP 1
RETURN
LOOP 2
RETURN
LOOP 3
RETURN
LOOP 1
OUT
LOOP 2
OUT
LOOP 3
OUT
LOOP 1
RETURN
LOOP 2
RETURN
LOOP 3
RETURN
IDENTIFYING COMPONENTS (cont...)
FIRE
FAULT
PRE-ALARM
TEST
DISABLED
SYSTEM ON
ALARM FAULT
ALARM SILENCE
AUXILIARY
RELAYS
DISABLED
TEST
FAUL
T
FIRE
FIRE BRIGADE
TRANSMISSION
SELECTED
DETECTORS
ACTIVE
DELAYS
SYSTEM RESET
SOUND ALARMS
LAMP TEST
JUNONET
SUPPLY FAULT
PROC. FAUL
T
TRANS. FAUL
T
FIRE BRIGADE
ACKNOWLEDGED
PAPER FEED
MANUF
ACTURED TO THE
REQUIREMENTS OF
EN54 PT 2 1999
QUEUE
REVIEW
F
IRE
A
LARM S
YST
EM
ALARM DISPLAY
FIRE
FAUL
T
PRE
-ALARM
TEST
DISABLED
SYSTEM ON
ALARM FAULT
ALARM SILENCE
AUXILIARY
RELAYS
DISABLED
TEST
FAULT
FIRE
FIRE BRIGADE
TRANSMISSION
SELECTED
DETECTORS
ACTIVE
DELAYS
SYSTEM RESET
SOUND ALARMS
LAMP TEST
JUNONET
SUPPL
Y FAUL
T
PROC. FAUL
T
TRANS. FAUL
T
FIRE BRIGADE
ACKNOWLEDGED
PAPER FEED
MANUF
ACTURED T
O THE
REQUIREMENTS OF
EN54 PT 2 1999
QUEUE
REVIEW
FI
R
E ALA
R
M
S
YST
E
M
ALARM DISPLAY
On both of these panels,
the first 1 or 3 loops are
found on the mainboard
that is attached to the
metallic fascia of the panel.
RS485 INTERFACE
(OPTIONAL)
Only used, if there are externally
connected Sub-Panels
5A POWER SUPPLY UNIT
MEANWELL
MODEL: LPP-150-27
INPUT: 85-264VAC ; 120-370VDC
OUTPUT: +27V 5.6A
47/63Hz
DANGER
220 VOLTS
5A POWER SUPPLY UNIT
MEANWELL
MODEL: LPP-150-27
INPUT: 85-264VAC ; 120-370VDC
OUTPUT: +27V 5.6A
47/63Hz
DANGER
220 VOLTS
1 2 3 4 5 6
ON
SNDR 1 SNDR 2
LOOP 1
OUT
LOOP 2
OUT
LOOP 3
OUT
LOOP 1
RETURN
LOOP 2
RETURN
LOOP 3
RETURN
AUX PS
POWER SUPPLY IN
0V 0V 0V24V 28V 28VMON
ETH
BATT
24V
EVAC
COMMS OK
COMMS FLT
PRE-ALARM
FAULT
5 VOLT FAULT
FIRE
PAN EL NO
SILENCE
A
CN4
MPX
CN5
CN3
H8/3003
311
100
50
311
100
50
311
100
50
311
100
50
311
100
50
311
100
50
311
100
50
272
4R7
35
1 2 3 4 5 6
ON
SNDR 1 SNDR 2
LOOP 1
OUT
LOOP 2
OUT
LOOP 3
OUT
LOOP 1
RETURN
LOOP 2
RETURN
LOOP 3
RETURN
AUX PS
POWER SUPPLY IN
0V 0V 0V24V 28V 28VMON
ETH
BATT
24V
EVAC
COMMS OK
COMMS FLT
PRE-ALARM
FAULT
5 VOLT FAULT
FIRE
PAN EL NO
SILENCE
A
CN4
MPX
CN5
CN3
H8/3003
311
100
50
311
100
50
311
100
50
311
100
50
311
100
50
311
100
50
311
100
50
272
4R7
35
1 2 3 4 5 6
ON
SNDR 1 SNDR 2
LOOP 1
OUT
LOOP 2
OUT
LOOP 3
OUT
LOOP 1
RETURN
LOOP 2
RETURN
LOOP 3
RETURN
AUX PS
POWER SUPPLY IN
0V 0V 0V24V 28V 28VMON
ETH
BATT
24V
EVAC
COMMS OK
COMMS FLT
PRE-ALARM
FAULT
5 VOLT FAULT
FIRE
PAN EL NO
SILENCE
A
CN4
MPX
CN5
CN3
H8/3003
311
100
50
311
100
50
311
100
50
311
100
50
311
100
50
311
100
50
311
100
50
272
4R7
35
J-NET RS 485 INT.
RS 485 OUT RS 485 IN
A AA AB BB B
TX 1 RX 1RX 2 TX 2
MAIN PANEL
SUB PANEL or
REPEATERS
J1 & J2 OFF
J2
J1
J1 & J2 ON
RS485 INTERFACE
(OPTIONAL)
Only used, if there are externally
connected Sub-Panels or Repeaters
J-NET RS 485 INT.
RS 485 OUT RS 485 IN
A AA AB BB B
TX 1 RX 1RX 2 TX 2
MAIN PANEL
SUB PANEL or
REPEATERS
J1 & J2 OFF
J2
J1
J1 & J2 ON
MAX 3A FAST ACTING
MAX 3A FAST ACTING
MAX 3A FAST ACTING
J-NET-CON
J-NET-CON
J-NET-LPCON
J-NET-LPCON
J-NET-SP with LOOP-CARD
J-NET-SP with LOOP-CARD
J-NET-SP with LOOP-CARD
J-NET-RS485-INT-NEW
J-NET-RS485-INT-NEW
AUX 1
PSU
AUX 2
PSU
BELL 1 BELL 2
24v
BATT
EVAC
ZONE
MPX
OUT PF E SF24v0v 0v
0v
CON 2
ZONE LED
CON 5
FIRE BRIG.
ACKNOWL.
INT. SUB PANEL
FIB.OPT. / RS-485
CON 1
TX
RX
LOADER
CON 6
PAL
NO
NO
FIR
NC
NC
NC
REPEATSAUX 2FAULT AUX 1
FLT
C
C
C
MAX 3A FAST ACTING
CON 7
AUX 1
PSU
AUX 2
PSU
BELL 1 BELL 2
24v
BATT
EVAC
ZONE
MPX
OUT PF E SF24v0v 0v
0v
CON 2
ZONE LED
CON 5
FIRE BRIG.
ACKNOWL.
INT. SUB PANEL
FIB.OPT. / RS-485
CON 1
TX
RX
LOADER
CON 6
PAL
NO
NO
FIR
NC
NC
NC
REPEATSAUX 2FAULT AUX 1
FLT
C
C
C
MAX 3A FAST ACTING
CON 7
14
Manufacturers of Fire Detection Equipment
INSTALLATION & COMMISSIONING MANUAL REVISION 4.0 05/2013
JUNO NET - NETWORKABLE ADRESSABLE PANEL
globalfire.pt