EasyManuals Logo

GW Instek APS-7000 Series User Manual

GW Instek APS-7000 Series
193 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #185 background imageLoading...
Page #185 background image
APPENDIX
185
APS-003 Option
Output Voltage 0 ~ 600 Vrms
Model
APS-7050
APS-7100
APS-7200
APS-7300
Output
Power Rating
500VA
1000VA
2000VA
3000VA
Maximum current
(r.m.s)
*5
0 ~ 600Vrms
1.05 A
2.1 A
4.2 A
6.3 A
Maximum current
(peak) 0 ~ 600Vrms
4.2 A
8.4 A
16.8 A
25.2 A
Setting
Voltage
Range
0 ~ 155 Vrms, 0 ~ 310 Vrms, 0 ~ 600 Vrms, Auto
Resolution
0.01V at 0.00 ~ 99.99 Vrms
0.1V at 100.0 ~ 600.0 Vrms
Accuracy
*6
± (0.5% of setting + 2 counts)
Measurement
*3
Voltage (r.m.s)
Range
0.2 ~ 600.0 Vrms
Resolution
0.01V at 0.00 ~ 99.99 Vrms
0.1V at 100.0 ~ 600.0 Vrms
Accuracy
± (0.5% of reading + 2 counts)
APS-004 Option
Output Frequency 45 ~ 1000 Hz
Model
APS-7050
APS-7100
APS-7200
APS-7300
Setting
Frequency
Range
45.00 ~ 1000 Hz
Resolution
0.01 Hz at 45.00 ~ 99.99 Hz
0.1 Hz at 100.0 ~ 999.9 Hz
1 Hz at 1000 Hz
Accuracy
± 0.02% of Setting
Measurement
*3
Frequency
Range
45.00 ~ 1000 Hz
Resolution
0.01Hz at 45.00 ~ 99.99Hz
0.1Hz at 100.0 ~ 999.9Hz
1 Hz at 1000 Hz
Accuracy
0.1/1 Hz

Table of Contents

Other manuals for GW Instek APS-7000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GW Instek APS-7000 Series and is the answer not in the manual?

GW Instek APS-7000 Series Specifications

General IconGeneral
BrandGW Instek
ModelAPS-7000 Series
CategoryAC Power Distribution
LanguageEnglish

Related product manuals