GDS-2000 Series User Manual
110
Use edge trigger
Panel operation
1. Press the Trigger menu key.
MENU
2. Press F1 repeatedly to select
edge trigger. The edge
trigger indicator appears at
the bottom of the display.
Type
Edge
F 1
From left: channel, edge trigger, slope
3. Press F2 repeatedly to select
the trigger source.
Source
CH1
F 2
Range
Channel 1 ~ 4, Line, Ext
4. Press F3 repeatedly to select
the trigger mode.
Mode
Auto
F 3
Range
Auto, Normal, Single
5. Press F5 (Slope/coupling) to
set trigger slope and
coupling.
Slope /
Coupling
F 5
6. Press F1 (Slope) repeatedly
to select the trigger slope,
which also appears at the
bottom of the display.
Range
Rising edge, falling edge
7. Press F2 (Coupling)
repeatedly to select the
trigger coupling.
Range
DC, AC

Table of Contents