Step 6 Follow these steps to set the detection rules and detection areas.
1) Select an Arming Region to configure. Up to 4 regions are selectable.
2) Drag the sliders to set Time Threshold and Sensitivity.
Time Threshold: The time of the objects removed from the region. If the value is 10,
alarm will be triggered after the object disappears from the region for 10s. Its range is
[5s-20s].
Sensitivity: The similarity degree of the background image. If the sensitivity is high, a very
small object taken from the region will trigger the alarm.
3) Click Draw Region and draw a quadrilateral in the preview window by specifying four vertices of
the detection region.
Step 7 Set the arming schedule. Refer to Chapter 11.1 Configure Arming Schedule.
Step 8 Set the linkage actions. Refer to Chapter 11.2 Configure Alarm Linkage Actions.
Step 9 Click Apply.
12.9 Audio Exception Detection
Purpose
Audio exception detection detects abnormal sounds in the surveillance scene, such as a sudden
increase/decrease in sound intensity.
Step 1 Go to System > Event > Smart Event.
Step 2 Click Audio Exception.
Figure 12-9 Audio Exception Detection
Step 3 Select a camera to configure.
Step 4 Optionally, check Save VCA Picture to save the captured audio exception detection pictures.
Step 5 Set the detection rules:

Table of Contents

Other manuals for HIKVISION DS-7732NI-I4/24P

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HIKVISION DS-7732NI-I4/24P and is the answer not in the manual?

HIKVISION DS-7732NI-I4/24P Specifications

General IconGeneral
BrandHIKVISION
ModelDS-7732NI-I4/24P
CategoryNetwork Hardware
LanguageEnglish

Related product manuals