Network Video Recorder User Manual
205
Figure 20-1 Windows task management interface
Select the “Performance” tab; check the status of the CPU and Memory.
If the resource is not enough, please end some unnecessary processes.
Step 7 Check if the fault is solved by the above steps.
If it is solved, finish the process.
If not, please contact the engineer from Hikvision to do the further process.
When using the device to get the live view audio, there is no sound or there is too much noise,
or the volume is too low.
Possible Reasons:
Cable between the pickup and IP camera is not connected well; impedance mismatches or
incompatible.
The stream type is not set as “Video & Audio”.
The encoding standard is not supported with device.
Step 1 Verify the cable between the pickup and IP camera is connected well; impedance matches and
compatible.
Log in the IP camera directly, and turn the audio on, check if the sound is normal. If not, please
contact the manufacturer of the IP camera.
Step 2 Verify the setting parameters are correct.
Go to Menu>Camera>Encoding Parameters, and set the Stream Type as “Audio & Video”.
Step 3 Verify the audio encoding standard of the IP camera is supported by the device.

Table of Contents

Other manuals for HIKVISION DS-7732NI-I4/24P

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HIKVISION DS-7732NI-I4/24P and is the answer not in the manual?

HIKVISION DS-7732NI-I4/24P Specifications

General IconGeneral
BrandHIKVISION
ModelDS-7732NI-I4/24P
CategoryNetwork Hardware
LanguageEnglish

Related product manuals