9.6 Message List
118
Message Data Contents Description
Ref
page
Comparator
:CALCulate:LIMit:STATe
1/ 0/ ON/ OFF
Sets and queries the comparator oper-
ating state.
131
:CALCulate:LIMit:STATe?
[ON/ OFF]
:CALCulate:LIMit:BEEPer
OFF/ HI/ LO/ HL/ IN
Sets and queries the beep sound. 131
:CALCulate:LIMit:BEEPer?
[OFF/ HI/ LO/ HL/ IN]
:CALCulate:LIMit:MODE
ABS/ REF
Sets and queries the decision mode. 132
:CALCulate:LIMit:MODE?
[ABS/ REF]
:CALCulate:LIMit:ABS
<Upper threshold>,
<Lower threshold>
Sets and queries ABS mode upper/
lower comparator threshold values.
132
:CALCulate:LIMit:ABS?
[<Upper threshold>,
<Lower threshold>]
:CALCulate:LIMit:REFerence
<reference resistance>
Sets and queries REF% mode refer-
ence resistance.
132
:CALCulate:LIMit:REFerence?
[<reference resistance>]
:CALCulate:LIMit:PERCent
<Upper threshold (%)>,
<Lower threshold (%)>
Sets and queries REF% mode upper/
lower comparator threshold percent-
ages.
132
:CALCulate:LIMit:PERCent?
[<Upper threshold (%)>,
<Lower threshold (%)>]
:CALCulate:LIMit:RESult?
[HI/ IN/ LO/ OFF/ ERR]
Queries the comparator result. 132
Self-Calibration
:SYSTem:CALibration
Execute self-calibration. 133
:SYSTem:CALibration:AUTO
1/ 0/ ON/ OFF
Sets and queries the automatic self-
calibration.
133
:SYSTem:CALibration:AUTO?
[ON/ OFF]
Key Beeper
:SYSTem:BEEPer:STATe
1/ 0/ ON/ OFF
Sets and queries the key beeper. 133
:SYSTem:BEEPer:STATe?
[ON/ OFF]
Line Frequency
:SYSTem:LFRequency
AUTO/ 50/ 60
Sets and queries the AC line frequen-
cy.
133
:SYSTem:LFRequency?
[AUTO/ 50/ 60]
Key-Lock
:SYSTem:KLOCk
1/ 0/ ON/ OFF
Sets and queries the key-lock. 134
:SYSTem:KLOCk?
[ON/ OFF]
Header Present
:SYSTem:HEADer
1/ 0/ ON/ OFF
Sets and queries header present. 134
:SYSTem:HEADer?
[ON/ OFF]
EOM Output
:SYSTem:EOM:MODE
HOLD/ PULSe
Sets and queries the EOM output
mode.
134
:SYSTem:EOM:MODE?
[HOLD/ PULSE]
:SYSTem:EOM:PULSe
0.001 to 0.100
Sets and queries the EOM pulse width. 134
:SYSTem:EOM:PULSe?
[0.001 to 0.100]