SCSI and I/O 8-41
Jumpers
This section descirbes jumper configurations for:
• TERMPWR
• SCSI ID
• Spindle Synchronization
• Write Protection
• Spin Delay
• Remote LED Displays
TERMPWR
TERMPWR is configured by installing the shunt jumper as shown in Figure 8-14 .
Figure 8-14. TERMPWR
Active Termination
The drive can be configured to provide active termination. Note the following considerations:
To configure the drive to provide active termination, install the jumper as shown in Figure 8-14 and across
Drive Location on the SCSI Bus Active Termination Configuration.
Drive installed at the end of the bus. If there is no separate bus terminator at the SCSI bus end containing the
drive, configure the drive to provide active termination.
Drive installed at the end of the bus. If a separator bus terminator is used at the SCSI bus end containing the
drive, configure the drive to not provide activer termination.
Drive not installed at the end of the
bus.
Configure the drive to not provide active termination.