4-26 Display Codes
BCH Warning Messages
When the BCH first comes up, these warning messages may be generated if problems or certain conditions
are found during selftest, initialization, or specific checks done in bootstrap code.
WARNING: Link to HP-PB I/O Expansion Module failed at 8/12.
Check cables and power to Expansion Module
then reboot machine.
An HP-PB Bus Converter installed in a 2- or 4-slot HSC Expansion I/O card at slot 8/12 has failed.
Check the cables and seating of the HP-HSC Expansion I/O card and reboot the system
.
WARNING: Link to HP-PB I/O Expansion Module failed at 8/8.
Check cables and power to Expansion Module
then reboot machine.
An HP-PB Bus Converter installed in a 2- or 4-slot HSC Expansion I/O card at slot 8/8 has failed.
Check the cables and seating of the HP-HSC Expansion I/O card and reboot the system.
WARNING: Link to HP-PB I/O Expansion Module failed at 8/4.
Check cables and power to Expansion Module
then reboot machine.
An HP-PB Bus Converter installed in a 2- or 4-slot HSC Expansion I/O card at slot 8/4 has failed.
Check the cables and seating of the HP-HSC Expansion I/O card and reboot the system.
WARNING: A 4 slot HSC I/O expansion was inserted--system cannot boot.
This computer model does not support 4 slot HSC I/O expansion.
Remove or replace with 2 slot HSC I/O before booting.
Your system does not support the Dual-Bus 4-Slot HP-HSC Expansion I/O module.
WARNING: A 3-D graphics card was inserted--system cannot boot.
This computer model does not support that 3-D graphics card.
Remove 3-D graphics card before booting.
3-D graphics cards are supported only in HP9000 K450/K460/Kx70/Kx80 systems.
WARNING: System integrity is at risk: Selftests have been disabled.
Enabling selftests with SER SEL ON will prevent this warning.
Selftests should be disabled only as needed during diagnostic testing and troubleshooting. Enter
the command SER SEL ON and re-boot the system.
WARNING: Memory is not configured for optimized performance due to
an improper grouping of module types.
Re-sequence the memory SIMMs in accordance with Appendix C of this manual.
WARNING: The processor(s) installed in this system do not match the
Hversion value stored in EEPROM on the system board.
Your system board may have the wrong processors installed. Replace the system board or proces-
sors as appropriate.
WARNING: Processors are not installed in numerical order (0 to 5).
Boot process has been halted. Refer to the “PR “ command in
the INFORMATION menu for processor configuration information.
Re-install processor boards in the correct sequence (see Chapter 7 of this manual) and re-boot the
system.