8-88 SCSI and I/O
Firmware Upgrade Failures:
Wrong firmware tape - The tape will be ejected within 1/2 to one minute of activity and no update will
have been done. (Match tape part number to product model number.)
Firmware tape used up - The tape will automatically be re-formatted by the drive as a normal data tape
and will no longer react as a firmware tape (This will occur after 200 passes).
Firmware tape write protected - The tape will be ejected and no update will be done.
Process interrupted at crucial point - If a power interruption occurs or activity on the SCSI bus
interferes, a DEAD DRIVE will be created.
Verify the upgrade by using appropriate diagnostic or utility. (SCSIDDS Interactive command
REVision)
Troubleshooting
The A3542A DDS-3 tape Unit is replaced as a single FRU.
Front Panel Status Display
Figure 8-51. A3542A Front Panel