DescriptionError
The tape thickness is too great to be handled properly by the servo system.7634h
An ATS speed change operation (AdjustSpeed) timed out waiting for tape to reach target
speed.
7635h
An ATS speed change operation (AdjustSpeed) was attempted while the tape was not moving.7636h
While trying to park the pin, LP2 was seen, but LP1 was not seen after rotating the grabber
CCW.
7637h
Threading timed out while waiting for the half moon to seat onto the back reel.7638h
Tape motion apparently stopped while waiting for head positioning to complete.7639h
Unthread timed out during the initial rewind of tape back into the cartridge.763Ah
Timed out during an operation to set tape position and speed.763Bh
Timed out during an operation to set the tape position.763Ch
Timed out during a RecoverTape operation.763Dh
The front reel did not rotate during the tape slack removal process.763Eh
Timed out waiting for back reel to reach position where leader block is fully seated.763Fh
Timed out waiting for back reel to rotate to the threading reversal point.7640h
Timed out waiting for back reel to rotate to the reverse threaded position.7641h
Timed out waiting for tension to be established during the reverse threading process.7642h
Timed out waiting for the reverse threading target position.7643h
Timed out waiting for leader block to detach during an unthread.7644h
Timed out waiting for tension to be established during the reverse unthreading process.7645h
Timed out waiting for speed to be established during the reverse unthreading process.7646h
A fatal reel fault occurred during the time when the tape was being stopped.7647h
Back reel stalled and was not rotating when determining thread direction.7648h
An operation that determines thread direction timed out.7649h
Warning: Tape speed error integrator value is very large.764Ah
Timed out waiting for back reel to rotate to the unthreading reversal point.764Bh
Timed out waiting for tape to reach unthreading reversal slow down point.764Ch
Timed out waiting for tape to reach unthreading turn around point.764Dh
Front reel turning CCW but should be CW after going through critical point during recover
tape process.
764Eh
Tape motion unexpectedly stopped during recover tape process of rewinding based on radius
estimate.
764Fh
Volume 1: hardware integration 125