Recovery process is using a secondary head set to perform a sensor calibration operation.766Bh
Recovery process is using a secondary head set to perform an azimuth calibration operation.766Ch
Servo calibration cannot be done now because it is too close to BOT.766Dh
Timed out waiting for half moon to approach head during a thread.766Eh
Timed out waiting for half moon to approach head during an unthread.766Fh
Timed out waiting for half moon to pass head during a thread.7670h
Timed out waiting for half moon to pass head during an unthread.7671h
Timed out waiting for half moon to enter guide during an unthread.7672h
Servo timing reference mismatch during timing reference calibration7673h
Set position and speed operation missed the target objectives by too much, probably due to
DSP retries.
7674h
Timed out waiting for the grabber to rotate enough to deactivate the tape lifter and lower
the tape onto the head
7675h
Cartridge Memory read after threading; mechanism parameters cannot be updated at this
time.
7676h
Mechanism sensors not in the expected state after a load command.7677h
Mechanism sensors not in the expected state after an unload command.7678h
Mechanism sensors not in the expected state after a grab command.7679h
Mechanism sensors not in the expected state after an ungrab command.767Ah
Deslacking process did not complete, probably due to the back reel motor failing to rotate.767Bh
FRM tension ramp process did not complete, probably due to excessive tape slippage in the
cartridge.
767Ch
FRM rotation was unexpectedly detected while ungrabbing the cartridge leader pin.767Dh
The calculated LPOS media manufacturers string checksum does not match what was read
from the tape.
767Eh
The LP sensor was asserted before loading, possibly because of a stuck or faulty sensor767Fh
The DSP was commanded to re-lock onto servo code. (This is a recovery algorithm.)7680h
A retry was necessary on a DSP seek command. (This is a recovery algorithm.)7681h
A retry was necessary on a DSP VI-sensor cal command. (This is a recovery algorithm.)7682h
A retry was necessary on a DSP azimuth cal command. (This is a recovery algorithm.)7683h
A retry was necessary on a DSP command to learn the VI-offset. (This is a recovery algorithm.)7684h
Unable to thread. An ungrab/regrab/rethread recovery process will now be attempted.7685h