Table 39 Error codes (part code 4005) (continued)
Severity
Level
Recommended ActionError MessageError
Number
Part
Code
WCheck the settings, then retry the
operation.
The cache residency size set for the CLPR
exceeds the maximum available cache
residency size.
CLPR No:%s
552444005
WCheck the settings, then retry the
operation.
The number of cache residency areas set
for the CLPR exceeds the maximum
available number of cache residency
areas.
CLPR No:%s
552454005
WCheck the settings, then retry the
operation.
The total number of Cache Residency
areas set for the CLPRs and the maximum
number of the Cache Residency areas
in the subsystem are not equal.
552464005
WCheck the settings, then retry the
operation.
The cache residency size set for the CLPR
is not a multiple of 512 MB.
CLPR No:%s
552474005
WCheck the settings, then retry the
operation.
The parity group that contains the
volume(s) to which Cache Residency is
set cannot be migrated to another CLPR.
Please remove the Cache Residency
settings from the volumes, and then
migrate the parity group.
CLPR No:%s
552654005
EIf this problem persists, please contact
HP Technical Support.
An error occurred during SVP
processing.
555304005
EIf this problem persists, please contact
HP Technical Support.
An error occurred during SVP
processing.
555314005
WSet the extent area within the size which
can be specified, then retry the
operation.
The specified extent is over the size
which can be specified.
555324005
EIf this problem persists, please contact
HP Technical Support.
An error occurred during SVP
processing.
555334005
EIf this problem persists, please contact
HP Technical Support.
An error occurred during SVP
processing.
555344005
EIf this problem persists, please contact
HP Technical Support.
An error occurred during SVP
processing.
555354005
EIf this problem persists, please contact
HP Technical Support.
An error occurred during SVP
processing.
555364005
EIf this problem persists, please contact
HP Technical Support.
An error occurred during SVP
processing.
555374005
WDisable the IO Suppression mode of this
volume, then retry the operation, or
remove the volume from the volumes to
be set.
Cache Residency cannot be set to the
specified volume because the IO
Suppression mode is set to Enable.
555384005
WEnable the Cache mode of this volume,
then retry the operation, or remove the
volume from the volumes to be set.
Cache Residency cannot be set for this
volume because its Cache mode is set
to Disable.
555394005
Part code 4005 107

Table of Contents

Other manuals for HP StorageWorks P9000 - Disk Arrays

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP StorageWorks P9000 - Disk Arrays and is the answer not in the manual?

HP StorageWorks P9000 - Disk Arrays Specifications

General IconGeneral
BrandHP
ModelStorageWorks P9000 - Disk Arrays
CategoryStorage
LanguageEnglish

Related product manuals