Table 59 Error codes (part code 7005) (continued)
Severity
Level
Recommended ActionError MessageError
Number
Part
Code
EMount the required PCB, then retry the
operation.
The PCB required for this operation is
not mounted. Check the subsystem
configuration.
584937005
EReplace the microcode, then retry the
operation.
The operation failed, because different
versions of microcodes coexisted in the
disk subsystem.
585207005
WRelease the journal volume setting, or
specify another volume.
The operation failed, because the
specified P-VOL was a journal volume.
585337005
WRelease the journal volume setting, or
specify another volume.
The operation failed, because the
specified S-VOL was a journal volume.
585347005
WRelease the journal volume setting, or
specify another volume.
The reserve volume setting failed
because the specified volume was a
journal volume.
585357005
WCheck the requirements for using the
volume with Continuous Access Journal.
The operation failed because the
specified S-VOL was a data volume of
Continuous Access Journal. Check the
requirements for using the volume with
Continuous Access Journal.
585367005
EAn error occurred on the DKC side. If
this problem persists, please contact HP
Technical Support.
An error occurred on the DKC side. If
this problem persists, please contact HP
Technical Support.
585727005
ECheck if the DKCMAIN and SVP
microcode versions are mismatched.
This function is not supported.585737005
EIf this problem persists, please contact
HP Technical Support.
An error occurred while connecting to
the subsystem. Please wait for a while,
and then retry the operation.
585747005
EIf this problem persists, please contact
HP Technical Support.
An error occurred while connecting to
the subsystem. Please wait for a while,
and then retry the operation.
585757005
EIf this problem persists, please contact
HP Technical Support.
A communication time-out error occurred
in the disk subsystem. Please wait for a
while, and then retry the operation.
585767005
WConfirm that the shredding has
completed in the Data Retention window,
then retry the operation.
The operation failed, because the
specified volume is being shredded by
Data Retention. Retry the operation after
the shredding is completed.
585797005
WThe specified command cannot be
executed with the current pair
composition.
See the section about the interoperability
with other products and functions and
the Business Copy described in the HP
StorageWorks P9000 Snapshot User
Guide for the condition of sharing the
volumes between Snapshot and Business
Copy.
The command has been rejected,
because the specified S-VOL is used as
P-VOL of Snapshot or the specified MU
number is already used.
585827005
WTo continue the operation, release the
Snapshot setting.
The operation failed because the volume
was shared by a Snapshot pair.
585837005
WCheck the conditions for using Business
Copy in conjunction with Snapshot.
The operation failed because the volume
was shared by a Snapshot pair in COPY
(RS-R) status.
585847005
234 Message (part code group 7nnn)

Table of Contents

Other manuals for HP StorageWorks P9000 - Disk Arrays

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP StorageWorks P9000 - Disk Arrays and is the answer not in the manual?

HP StorageWorks P9000 - Disk Arrays Specifications

General IconGeneral
BrandHP
ModelStorageWorks P9000 - Disk Arrays
CategoryStorage
LanguageEnglish

Related product manuals