Scenarios
Remove a compute module if:
● The compute module has failed.
● The CPU on the compute module has failed.
Prerequisites
Conditions
You have powered
o the RH8100 V3. For details, see 6.2 Powering O the
RH8100 V3. Then you have removed all power cables from the server.
Data
● You have obtained the cabinet number and chassis number of the RH8100 V3.
● You have located the RH8100 V3 based on the preceding information, and
labeled its panel to prevent misoperations.
● You have determined the position on the RH8100 V3 for removing a compute
module.
Tools
● ESD gloves
● Packaging materials, for example, an ESD bag
Procedure
Step 1 Wear an ESD wrist strap or ESD gloves. For details, see 1 Safety Instructions.
Step 2 Ensure that the system where the compute module is located is powered
o (the
power indicator of the system is o). Press the ejector release buttons to eject the
ejector levers. See step (1) in Figure 5-1.
Step 3 Raise both ejector levers on the compute module. See step (2) in Figure 5-1.
Step 4 Gently pull the compute module out of the slot while holding the ejector levers.
See step (3) in Figure 5-1.
RH8100 V3 Server
User Guide 5 Removing and Installing Parts of the RH8100 V3
Issue 30 (2019-12-19) Copyright © Huawei Technologies Co., Ltd. 109