Scenarios
Remove a compute module if:
The compute module has failed.
The CPU on the compute module has failed.
Prerequisites
Conditions
You have powered
o the RH8100 V3. For details, see 6.2 Powering O the
RH8100 V3. Then you have removed all power cables from the server.
Data
You have obtained the cabinet number and chassis number of the RH8100 V3.
You have located the RH8100 V3 based on the preceding information, and
labeled its panel to prevent misoperations.
You have determined the position on the RH8100 V3 for removing a compute
module.
Tools
ESD gloves
Packaging materials, for example, an ESD bag
Procedure
Step 1 Wear an ESD wrist strap or ESD gloves. For details, see 1 Safety Instructions.
Step 2 Ensure that the system where the compute module is located is powered
o (the
power indicator of the system is o). Press the ejector release buttons to eject the
ejector levers. See step (1) in Figure 5-1.
Step 3 Raise both ejector levers on the compute module. See step (2) in Figure 5-1.
Step 4 Gently pull the compute module out of the slot while holding the ejector levers.
See step (3) in Figure 5-1.
RH8100 V3 Server
User Guide 5 Removing and Installing Parts of the RH8100 V3
Issue 30 (2019-12-19) Copyright © Huawei Technologies Co., Ltd. 109