Figure 5-122 Installing a RAID controller card
Step 5 Insert the cables to the RAID controller card. See step (3) in Figure 5-122.
----End
5.8.9 Removing a Supercapacitor
This topic describes how to remove a supercapacitor.
Scenarios
You can
congure a supercapacitor to provide power failure protection for the
LSISAS3108 controller card. Remove a supercapacitor if:
The supercapacitor has failed.
The supercapacitor is low.
Prerequisites
Conditions
You have powered
o the RH8100 V3. For details, see 6.2 Powering O the
RH8100 V3. Then you have removed all power cables from the server.
You have removed the front I/O module from the RH8100 V3. For details, see
5.8.1 Removing the Front I/O Module.
Data
You have obtained the cabinet number and chassis number of the RH8100 V3.
You have located the RH8100 V3 to be removed based on the preceding
information, and have labeled its panel to prevent misoperations.
You have determined the position on the RH8100 V3 for removing a
supercapacitor.
RH8100 V3 Server
User Guide 5 Removing and Installing Parts of the RH8100 V3
Issue 30 (2019-12-19) Copyright © Huawei Technologies Co., Ltd. 244