When the server is in single-system mode, pressing the primary power
button on the front panel to power o the server.
When the server is in dual-system mode, pressing the primary power
button on the front panel to power o system A and pressing the
secondary power button on the front panel to power o system B.
Hold down the power button on the front panel to power
o the server.
If you use this method to power o and then on a server when a fault occurs,
some information may be missing in the fdm_log le that records
information collected through the one-click information collection function of
the management software. Avoid using this method to power
o and then on
a server when a fault occurs.
When the server is in single-system mode, hold down the primary power
button on the front panel to power
o the server.
When the server is in dual-system mode, hold down the primary power
button on the front panel to power
o system A and hold down the
secondary power button on the front panel to power o system B.
In the remote management scenario, use the iBMC CLI to power
o the
server.
When the server is in single-system mode, run the ipmcset -d
powerstate -v 0 command on the iBMC CLI to remotely power
o the
server.
When the server is in dual-system mode, run the ipmcset -d powerstate
-v 0 command on the iBMC CLI of system A to remotely power
o
system A and run this command on the iBMC CLI of system B to remotely
power
o system B.
Use the iBMC WebUI to power o the server.
When the server is in single-system mode, log in to the iBMC WebUI,
choose Power on the menu bar, choose Power Control in the navigation
tree, and click Power
O and then OK to power o the server.
When the server is in dual-system mode, log in to the iBMC WebUI of
system A, choose Power on the menu bar, choose Power Control in the
navigation tree, click Power
O and then OK to power o system A.
Then log in to the iBMC WebUI of system B, and repeat the follow-up
operations to power
o system B.
RH8100 V3 Server
User Guide 6 Powering On and O the RH8100 V3
Issue 30 (2019-12-19) Copyright © Huawei Technologies Co., Ltd. 306