v 1.4 — September 2015 Altanium Neo2
28 Security Item Descriptions
Zone Alarm Window Enables the operator to adjust the value for the ALARM condition.
Zone Sensor Input Enables the operator to reassign Thermocouple Inputs.
Zone Name Enables the operator to change the name of the zone.
Zone ON / OFF Enables the operator to turn a zone ON or OFF.
Zone Setpoint Limits Enables the operator to make changes to the minimum and maximum
setpoint limits. These limits are used to prevent a setpoint from being set
too high or too low depending on the requirement of the process.
Standby Setpoints Enables the operator to adjust the Standby setpoints in the System
screen.
Boost Setpoints Enables the operator to adjust the Boost setpoints in the System screen.
Zone Regulation Enables the operator to adjust the zone regulation mode between AUTO
and MANUAL modes.
Zone Slave Enables the operator to manually select a zone to follow the power
output control of a different zone should the thermocouple fail.
Zone Output Enables the operator to specify which power output control method to
use: Zero-Cross (Z/C) or Phase Angle (P/A).
Priority Control Mode Enables the operator to select the zone shutdown sequence between
ZONE and SYSTEM in an abort condition. If ZONE is selected ONLY the
zone will turn OFF, but if SYSTEM is selected ALL zones will turn OFF.
Automatic Manual
Control
Enables the operator to enable the zone to continue running when the
thermocouple fails. The zone is supplied with an averaged power output
percentage in Manual Control Mode, based on the history of that same
zone.
Zone Earth Leakage Enables the operator to turn the earth leakage check On or Off.
Zone Power Limit Enables the operator to assign a power limit value to an individual zone
per mold setup. Power Limiting is defined in percentage (0%-100%) and
is used to prevent the controller from delivering full power to a heater.
Zone Control Enables the operator to change between ART or PID as the control
method.
Zone PID Enables the operator to adjust the P-I-D parameters in the ART/PID
screen.
Mold Setup File Load Enables the operator to load Mold Setups from the Molds screen.
Mold Setup File Copy Enables the operator to copy a stored mold setup to a different location.
Mold Setup File Default Enables the operator to delete the contents of a stored mold setup and
return all values to Husky's default.
Mold Setup
Import/Export
Enables an operator to import or export a mold setup using a USB disk.
Temperature Units Enables the operator to toggle the displayed temperature units
between °F and °C.
Feature Description