Powermax65/85/105 SYNC Troubleshooting Guide 810430 139
TP – This field shows the boost PFC IGBT temperature in Celsius. This field shows on the screen
for CSA and for Powermax105 SYNC 230 V – 400 V CE models only.
TI – This field shows the inverter IGBT temperature in Celsius.
STA – This field shows the total number of torch starts the plasma power supply has done in its life.
XFR This field shows the total number of arc transfers the plasma power supply has done in its
life.
PT – This field shows the cumulative pilot arc time in hours, minutes, and seconds (HH:MM:SS)
that the plasma power supply has had in its life.
XT – This field shows the cumulative arc transfer time in hours, minutes, and
seconds (HH:MM:SS) that the plasma power supply has had in its life.