Powermax65/85/105 SYNC Troubleshooting Guide 810430 149
Show cartridge data on the status screen
You can show the cartridge data for pilot arc starts (STA) and arc transfer time (XT) on the status
screen. When you set the STA/XT field to on, these values stay on the status screen until you set
the STA/XT field to off.
1. Push and hold for 2 seconds to go to the main menu screen.
2. Turn the adjustment knob to go to . Push to select it.
3. Turn the adjustment knob to go to , and push to select it. The LCD Display screen
(LCD DISPLAY) shows.
4. Turn the adjustment knob to go to the STA/XT field, and push to select it.
5. Turn the adjustment knob to set the STA/XT field
to on: .
6. Push to apply the setting.