Troubleshooting for Fault Codes
3
Powermax65/85/105 SYNC Troubleshooting Guide 810430 43
Fault
code
Fault
icon
Fault
LEDs Description Solutions
0-11-0
Flashes
yellow
The remote control operating
mode is incorrect or not
permitted for the installed
cartridge.
The permitted operating
modes for cutting cartridges
are 1 (Cut mode) and 2
(Expanded Metal mode). The
permitted operating mode for
a gouging cartridge is 3
(Gouge mode).
These fault codes do not stop the system from
operating. Hypertherm recommends that you do
the following.
There is a problem with the remote control or
the software interface to the system. The system
cannot interpret the operating mode, output
current, or gas pressure information coming
from the controller.
Examine the programming code for
incorrect process variables.
Repair the controller.
0-11-1 The remote control output
current (A) is incorrect or not
permitted for the installed
cartridge.
The permitted values relate to
the minimum and maximum
output current (A) for the
plasma power supply and the
installed cartridge.
0-11-2 The remote control gas
pressure is incorrect or not
permitted.
The permitted gas pressure
relates to the selected
process and operating mode,
and to the installed torch,
torch lead, and cartridge.

Table of Contents

Other manuals for Hypertherm Powermax65 SYNC

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hypertherm Powermax65 SYNC and is the answer not in the manual?

Hypertherm Powermax65 SYNC Specifications

General IconGeneral
BrandHypertherm
ModelPowermax65 SYNC
CategoryWelding System
LanguageEnglish

Related product manuals