EasyManuals Logo

Hypertherm Powermax65 SYNC Troubleshooting Guide

Hypertherm Powermax65 SYNC
180 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #89 background imageLoading...
Page #89 background image
Do System Tests to Identify Defective Components
5
Powermax65/85/105 SYNC Troubleshooting Guide 810430 89
Figure 14 – Powermax65/85 SYNC test points
Figure 15 – Powermax105 SYNC test points
TP13
TP11
TP12
W
R
B
J23
J24
J30
J29
TP12
TP10
TP11
W
R
B
CSA
Test points Resistance
TP10 and TP12 25 k
TP11 and TP12 25 k
CE / CCC
Test points Resistance
TP11 and TP13 18 k
TP12 and TP13 18 k
J27
WORK
LEAD
J26
+
_
C152
TP7
TP9
TP8
W
R
B
200 V 600 V CSA / 230 V 400 V CE
Test points Resistance
TP7 and TP9 25 k
TP8 and TP9 25 k
380 V CCC / 400 V CE
Test points Resistance
TP7 and TP9 18 k
TP8 and TP9 18 k

Table of Contents

Other manuals for Hypertherm Powermax65 SYNC

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hypertherm Powermax65 SYNC and is the answer not in the manual?

Hypertherm Powermax65 SYNC Specifications

General IconGeneral
BrandHypertherm
ModelPowermax65 SYNC
CategoryWelding System
LanguageEnglish

Related product manuals