Connect for Communication
4
164 809480 Instruction Manual XPR300
2. Connect one end of the VDC3 120 VAC harness to J1 of the VDC3 board with the tab on top,
as shown in Figure 47.
3. Connect the other end of the VDC3 120 VAC harness to the 120 VAC connector.
Figure 47
4. Attach the spade connector of the yellow wire (WORK) to the J3-WORK terminal, as shown
in Figure 48.
5. Attach the spade connector of the yellow/black wire (NEG) to the J3-ELECTRODE terminal.
Figure 48
NEG
WORK
ELECTRODE
WORK
SHIELD
GND
J3

Table of Contents

Other manuals for Hypertherm XPR300

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hypertherm XPR300 and is the answer not in the manual?

Hypertherm XPR300 Specifications

General IconGeneral
Cutting Current300 A
Duty Cycle100% at 300 A
TechnologyX-Definition Plasma
Gas SupplyOxygen, Nitrogen, Air
Cutting Capacity (Mild Steel)38 mm (1.5 in)
Severance Capacity (Mild Steel)75 mm (3 in)
Pierce Capacity (Mild Steel)50 mm (2 in)
Input Voltage200–480 V, 3-PH, 50/60 Hz