Diagnostics and Troubleshooting
8
XPR300 Instruction Manual 809480 281
570
Alert
Start on Powerup The Plasma Start switch is in
the ON position before the
cutting systems goes into
Powerup State.
Refer to Start switch diagnostic codes (570 – 577)
on page 325.
None Start or set
process;
remote on-off
571
Alert
Start on wait-start The Plasma Start switch is in
the ON position before the
cutting system goes into
Wait-for-Start State.
None Start or set
process;
remote on-off
574
Info
Start removed
preflow
The Plasma Start switch is in
the OFF position during
Preflow State.
Refer to Start switch diagnostic codes (570 – 577)
on page 325.
End of cycle Start or set
process;
remote on-off
575
Info
Start removed
ignite
The Plasma Start switch is in
the OFF position during
Ignite State.
End of cycle Start or set
process;
remote on-off
576
Info
Start removed pilot The Plasma Start switch is in
the OFF position during Pilot
arc State.
End of cycle Start or set
process;
remote on-off
577
Info
Start removed
rampup
The Plasma Start switch is in
the OFF position during a
Ramp-Up State.
End of cycle Start or set
process;
remote on-off
Diagnostic code
number and
category
Diagnostic code
name
Description Corrective action XPR action