Diagnostics and Troubleshooting
282 809480 Instruction Manual XPR300
580
Error
Over temp-Ind1 The temperature of
Inductor 1 (1A) or 2 (1B) is
more than 160°C (320°F).
When conditions are normal,
it takes approximately 10
minutes for the XPR cutting
system to cool.
Over-temp codes can occur
when cooling takes more
than 10 minutes.
A high ambient temperature
can have an effect on cooling
time.
Refer to Over temp diagnostic codes – Inductors
(580 – 583), Transformers (586) on page 327.
Ramp down —
581
Error
Over temp-Ind2 Ramp down —
582
Error
Over temp-Ind3 The temperature of
Inductor 3 (2A) or 4 (2B) is
more than 160°C (320°F).
When conditions are normal,
it takes approximately 10
minutes for the XPR cutting
system to cool.
Over-temp codes can occur
when cooling takes more
than 10 minutes.
A high ambient temperature
can have an effect on cooling
time.
Refer to Over temp diagnostic codes – Inductors
(580 – 583), Transformers (586) on page 327.
Ramp down —
583
Error
Over temp-Ind4 Ramp down —
586
Error
Over temp-Xfmr For a minimum of 5 seconds,
the temperature of the
transformer is more than
160°C (320°F).
Refer to Over temp diagnostic codes – Inductors
(580 – 583), Transformers (586) on page 327.
Ramp down —
587
Error
Over temp-Coolant The coolant temperature is
more than 85°C (185°F).
Refer to Over temp diagnostic codes – Choppers
(560 – 561) and Coolant (587) on page 322.
Ramp down —