EasyManua.ls Logo

Hypertherm XPR300 - Page 283

Hypertherm XPR300
438 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Diagnostics and Troubleshooting
8
XPR300 Instruction Manual 809480 283
588
Failure
Fan timeout Fan timeout codes can occur
when cooling takes more
than 1 hour.
A high ambient temperature
can have an effect on cooling
time.
1. Identify the over-temp diagnostic codes that
appear on the XPR web interface.
2. Follow the troubleshooting steps for the codes.
Shut down
600
Error
No TCC found For a minimum of 30 seconds
after power is supplied to the
cutting system, the torch
connect console does not
identify itself to the main
control PCB through the
CAN.
Refer to CAN codes (500 – 503, 510 – 513 for gas
connect console, 504 – 505, 514 – 515 for CAN
cable and jumper block, 507 – 508 for CAN
network and bus, 600 – 602 for no CAN
communication) on page 311.
Shut down Remote on-off
601
Error
No chopper found For a minimum of 30 seconds
after power is supplied to the
cutting system, Chopper 1
does not identify itself to the
main control PCB through
the CAN.
1. Confirm that the chopper ID connector is
connected to J8.
2. Connect the connectors if necessary.
3. If connected, refer to CAN codes (500 – 503,
510 – 513 for gas connect console, 504
505, 514 – 515 for CAN cable and jumper
block, 507 – 508 for CAN network and bus,
600 – 602 for no CAN communication) on
page 311.
Shut down Remote on-off
602
Error
No GCC found For a minimum of 30 seconds
after power is supplied to the
cutting system, the gas
connect console (Core, VWI,
or, OptiMix) does not identify
itself to the main control
PCB.
Refer to CAN codes (500 – 503, 510 – 513 for gas
connect console, 504 – 505, 514 – 515 for CAN
cable and jumper block, 507 – 508 for CAN
network and bus, 600 – 602 for no CAN
communication) on page 311.
Shut down Remote on-off
Diagnostic code
number and
category
Diagnostic code
name
Description Corrective action XPR action
Code cancels
with

Table of Contents

Other manuals for Hypertherm XPR300