Diagnostics and Troubleshooting
8
284 809480 Instruction Manual XPR300
604
Alert
No Chopper 2
found
The inductor thermocouples
for Chopper 2 were detected,
but Chopper 2 was not
detected.
1. Make sure that the connector (J8) on
Chopper 2 is fully engaged.
2. Make sure that the connector (J2) on
Chopper 2 is fully engaged.
3. If connected, refer to CAN codes (500 – 503,
510 – 513 for gas connect console, 504
505, 514 – 515 for CAN cable and jumper
block, 507 – 508 for CAN network and bus,
600 – 602 for no CAN communication) on
page 311.
None Start or set
process;
remote on-off
610
Failure
Ch1 Torch Protect
ChA
A catastrophic failure of a
consumable part is found on
the Channel A Chopper 1
current signature.
1. Inspect the consumable parts for damage and
excess wear.
2. If any consumable part needs replacement,
refer to Install the consumables on page 133.
Ramp down Remote on-off
611
Failure
Ch1 Torch Protect
ChB
A catastrophic failure of a
consumable part is found on
the Channel B Chopper 1
current signature.
Ramp down Remote on-off
612
Failure
Ch2 Torch Protect
ChA
A catastrophic failure of a
consumable part is found on
the Channel A Chopper 2
current signature.
1. Inspect the consumable parts for damage and
excess wear.
2. If any consumable part needs replacement,
refer to Install the consumables on page 133,
Ramp down Remote on-off
613
Failure
Ch2 Torch Protect
ChB
A catastrophic failure of a
consumable part is found on
the Channel B Chopper 2
current signature.
Ramp down Remote on-off
Diagnostic code
number and
category
Diagnostic code
name
Description Corrective action XPR action