Diagnostics and Troubleshooting
XPR300 Instruction Manual 809480 295
716
Error
Process Invalid The operator-selected
process is not supported by
this XPR cutting system.
Smart-fault data values:
Refer to the smart-fault data value (number) that
accompanies the diagnostic code in the XPR web
interface to identify the unsupported process and
best corrective action for each:
None Set process;
remote on-off
1: invalid id
Process ID = 0
Refer to the XPR Cut Charts Instruction Manual
(809830) for guidance about how to select the
process ID for a supported process.
None Set process;
remote on-off
2: invalid user
Another interface has control
of the cutting system.
Only 1 communication
method (Serial, EtherCAT or
Wireless) at a time can send
a process ID to the XPR
cutting system.
Refer to the Connect for Communication on
page 147 and How to change the device that has
control on page 192 for guidance about how to
select or change the interface that controls the
cutting system.
None Set process;
remote on-off
3: invalid user source
Another interface has control
of the cutting system.
Only 1 wireless interface at a
time can send a process ID
to the XPR cutting system.
None Set process;
remote on-off
4: invalid process
Incorrect process ID was
sent.
Refer to the XPR Cut Charts Instruction Manual
(809830) for guidance about how to select the
process ID for a supported process.
None Set process;
remote on-off
Diagnostic code
number and
category
Diagnostic code
name
Description Corrective action XPR action
Code cancels
with